Return to site

Zemax Optical Design Software Free Download

broken image


Japanese download page

SENSITIZER is an ESO software toolset written in Matlab and Mathematica aiming at automating some Structural/Thermal/Optical Performance (STOP) sensitivity analyses with Zemax OpticStudio (ZOS). The core code of SENSITIZER runs in MATLAB and drives ZOS in the background through the ZOS-API interface, based on.NET. The perfect complement to OpticStudio. Each engineer owns their part of the product development process, and up until now, engineers that work with optical engineers have not had access to optical design data to troubleshoot and analyze how the optical. The forum gives you the opportunity to engage in discussions with other Zemax software users and Zemax support staff. It's a place to swap ideas and have meaningful conversations around design challenges you face. Turmoil free to play. Websites that sell unlocked phones without. On our forums, no question is too big or too small. Zemax's optical and mechanical design software, OpticStudio® and OpticsBuilder®, turn optical and illumination systems ideas into reality. Standardizing on Zemax software for optomechanical design reduces development iterations and repeated physical prototypes, and speeds time to market. Zemax Opticstudio OpticStudio is the essential software platform for optical engineers, combining an intuitive user interface with complex physics and interactive visuals to drive faster innovation while reducing development costs. Optical crack software download prg paulin pls mail. Leading Optical Product Design Software for Engineering Teams.


Current Versions:

FilenameDateSizeDescription
OpTaliX-Pro 32/64 bit V10.60, UPDATE
Requires purple Sentinel/HASP key.
MD5-Checksum:
77255501D2CD684B34F9458A14759E5A optalix_pro_update_1060.exe
03. Oct.
2020
62.11 MBOpTaliX-Pro update for 32-bit and 64-bit single- and multi-processor versions. Requires a full installation and a valid upgrade license before this upgrade can be installed. See also the version history for the latest changes respectively improvements.
OpTaliX-Pro NET 32/64 bit V10.60, UPDATE
Requires red Sentinel/HASP network key.
MD5-Checksum:
36090BF11FD00A380898F8427EC9F4AD optalix_pro_update_NET_1060.exe
03. Oct.
2020
62.11 MBOpTaliX-Pro update for 32-bit and 64-bit single- and multi-processor versions. Requires a full installation and a valid upgrade license before this upgrade can be installed. See also the version history for the latest changes respectively improvements.
OpTaliX-LT 10.50
(Free download, 30 days trial)
Purchase a permanent license of OpTaliX-LT
MD5-Checksum:
B3FC2E7B6667816475F16A0AD020D08E optalix_lt_setup_1050.exe
07. Aug.
2020
28.81 MBOpTaliX-LT is a functionally reduced version of OpTaliX-PRO and focusses on geometrical analyses only. OpTaliX-LT is shareware. You may use it 30 days for free. After this period you should register OpTaliX-LT. OpTaliX-LT runs on Windows versions XP/Vista/7/8/10, both 32-bit and 64-bit operating systems. The latest changes and improvements are summarized in the version history.
Handbook of Optical Systems. Optical Design Files
Jan. 2009406 KBAll optical design files presented in the 'Handbook of Optical Designs', Vol. 4, from Wiley in the OpTaliX format. Download OpTaliX-LT to open, view and analyze the files, or eventually convert the designs to other formats (Code V, Zemx, Oslo, ASAP).
Note: Make sure to check the option 'recurse folders' when extracting the archive.

Obsolete Versions:

FilenameDateSizeDescription
OpTaliX-Pro-32bit V7.98, update
For Hardlock key (blue) only
Requires an existing 7.24 installation
MD5-Checksum:
A748BC3F56BE004F491CB4B29F960A9C optalix_pro_update_798_hardlock.exe
27.Jan.
2013
25.58 MBOpTaliX-Pro update for users with Hardlock key (blue). Note that support of this version has expired. This version (7.98) is the last version available for this type of hardware key (Hardlock). Users with a valid upgrade license are eligible to upgrade to the most recent version (9.70) at no charge.
OpTaliX-Pro Server 7.64, update
Requires an existing 7.24 installation
Requires Hardlock server hardware key
MD5-Checksum:
4171006D48140F0C9DC32C0ACFB16700 optalix_pro_upd_serv_764.exe
22.May
2012
26.13 MBThis is the version 7.64 update for OpTaliX-Pro-Server. It requires an existing installation and can only be applied if version 7.24 (server) or higher is already installed. To run this version you need a server hardware key (aka 'dongle'). Please download PDF manuals separately (see below). See also the version history for the latest changes respectively improvements.

Manuals and Drivers:

FilenameDateSizeDescription
Reference Manual 10.50Aug. 20206.08 MBPDF reference manual with numerous internal hyperlinks for easier navigation. It explains all commands available in OpTaliX-LT, OpTaliX-PRO and OpTaliX-EDU. Copy the file into the directory where OpTaliX is installed.
Tutorial 6.5011.June
2006
1.54 MBPreliminary version of the OpTaliX tutorial. It is not complete but will be constantly extended. As for the reference manual, the tutorial is a PDF file with numerous internal hyperlinks for easier navigation. Copy the file into the directory where OpTaliX is installed.
Handbook of Optical Systems
Vol. 4, Design Files
Jan-20090.41 MBAll design files presented in the 'Handbook of Optical Deigns', Vol. 4, from Wiley in the OpTaliX format. Download OpTaliX-LT to convert the designs to other formats (Code V, Zemax, Oslo, ASAP).
June 202021.26 MBSentinel/HASP driver software for Windows Windows Vista, Win7, Win8, Win10, for both 32-bit and 64-bit systems.
It is strongly recommended to upgrade to this driver.
Optical

Minimum hardware requirements:

- Pentium 4, 1GHz,
Software
- 3 GByte RAM,
- 200 MByte available on hard disc,
- Windows XP/Vista/Win7/Win8/Win10 operating systems required,
- 1024 x 768 pixel monitor resolution or higher recommended.
Should you experience problems to download, install or run OpTaliX, please contact us at .
OpTaliX offers comprehensive import and export routines to convert lens prescriptions from other optical design programs such as Code V, Oslo, ZEMAX, ASAP, Atmos, Modas Accos, Sigma2000 and WinLens. Conversion can be done in both ways, that is, from other programs (import) or to other programs (export). At present, WinLens files can only be imported.
Free

Minimum hardware requirements:

- Pentium 4, 1GHz,
- 3 GByte RAM,
- 200 MByte available on hard disc,
- Windows XP/Vista/Win7/Win8/Win10 operating systems required,
- 1024 x 768 pixel monitor resolution or higher recommended.
Should you experience problems to download, install or run OpTaliX, please contact us at .
OpTaliX offers comprehensive import and export routines to convert lens prescriptions from other optical design programs such as Code V, Oslo, ZEMAX, ASAP, Atmos, Modas Accos, Sigma2000 and WinLens. Conversion can be done in both ways, that is, from other programs (import) or to other programs (export). At present, WinLens files can only be imported.

Zemax Optical Studio

The import/export capabilities of OpTaliX are comprehensive in a way that also advanced features like decenters, tilts, gradients, gratings, special apertures, etc are recognized and converted.
Note, however, that it is virtually impossible to convert ALL features offered by various optical design programs. Not only that features are implemented in a completely different manner because program philosophies are vastly divergent, the major problem is lack of documetation about the formats how design data are stored. To the extreme, some vendors are trying to obscure format details to the maximum possible extent. Quite often the only rescue out of this problem is by 'reverse engineering'. This is a tedious process. Another problem is that file formats are often changed without prior notice, for example if new features are added. This may lead to the situation that a feature that could be previously converted without problems now eventually leads to inappropriate conversion results. Despite all of these difficulties, OpTaliX attempts to recognize a maximum amount of commands and features stored in external lens design files.
Imported files can be viewed, analyzed and modified in all versions of OpTaliX, including OpTaliX-LT. Go to the download page to obtain your copy of OpTaliX-LT (30 days free, after this period registration is required).
OpTaliX-LT converts the following prescription items to/from Code V, Zemax, Oslo, Atmos, Modas, WinLens, Accos and Sigma PC/2000 :

Zemax Software

Legend: = fully converted
NA = not applicable. This feature is not offered by the designated program.
blank cells denote features, which are not converted yet, but are on the wish list.

ACCOS and Sigma2000 are outdated and are no longer commercially available. Therefore, only import facilities will be provided for these programs. This allows you to convert old ACCOS and SIGMA-files to more recent optical design packages. Since the WinLens file format has undergone numerous modifications in the past, export to WinLens will only be offered when there is a stable format and a demand for it.
Sigma-PC
ZEMAXOSLOCODE-VMODASATMOSWinLensACCOSSigma2000
imp. exp. imp. exp. imp. exp. imp. exp. imp. exp. imp. exp. imp. exp. imp. exp.
System Definition:
System Aperture (F-number, num. aperture, ..)6666
ApodizationNANANANANANA
Fields (angle, object / image height)7777
Field weightsNANANANANANA
Wavelengths9
Wavelength weightNANANANA
Reference wavelengthNANANANANANA
System notes11
Surfaces
Sphere
Asphere + Toric8888
Tilted5NANA
Tilt orderNANANANA
Decentered33NANA
Pickups (thickness, curv., glass, aperture)NANANANANANA
GratingNANANANANANA
Holograms (2-point)NANANANANANA
Comments, NotesNANANANANANA
Mirrors
Ideal lensNANANANANANA
Glass catalogue names
Surface Apertures:
circular
rectangularNANANANA
ellipticalNANANANANANA
obstructionNANANANA
multiple aperturesNANANANANANA
aperture decenterNANANANANANA
Gradient Index:
LightPath GradiumNANANANANANA
SelfocNANANANANANA
GLCNANANANANANA
mixed gradientNANANANANANA
Miscellaneous:
Afocal22NANANANANANA
Telecentric beams4NANANANANANA
SolvesNANANANA
Special Aperture PickupsNANANANANANA
Zoom / MulticonfigurationNANANANA10

Zemax Software Download


Notes:

Zemax Optical Design software, free download Windows 7

1 Only the lens system title is converted (TIT command).
2 Since ZEMAX does not offer an 'afocal' mode, an ideal lens is added to the exported system. On import, the ideal lens is recognized and maintained.
3 Z-decenter are not supported by ZEMAX. A dummy surface is inserted to simulate Z-decenter.
4 Two additional surfaces are added on export to ZEMAX to approximate telecentric beams.
5 An additional 'coordinate break' surface is added on export to ZEMAX to exactly model tilted surfaces.
6 ATMOS and MODAS only recognize entrance pupil diameter, as defined by the first surface.
7 ATMOS and MODAS only support a maximum field angle in object space.
8 Toric surfaces are not supported by ATMOS and MODAS.
9 WinLens accepts only 5 wavelengths.
10 WinLens accepts only 4 zoom positions.




broken image